← OSHA severe injury reports

Fractures

1 hospitalization · 20241110831 · 11/20/2024 · Service Electric Company

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Leg(s) unspecified
Nature of injury
Fractures

Cause

Event
Caught, entangled in running powered equipment normal operation
Source
Skid-steer loaders, mini loaders
Secondary source
Beams and rails metal

Employer

Name
Service Electric Company
Location
1200 Seagrove St., SAINT MARYS, GEORGIA, 31558
NAICS
237130
Jurisdiction
1

Narrative

Employee 1 had just finished disassembling a metal girder structure on the ground and had removed the bolts from its metal cross brace. Employee 1 then moved to the left side of the structure. Employee 2 was using a skid steer to pick up the metal cross brace. Once the cross brace was on the forks of the skid steer, employee 1's right leg was caught between the cross brace and the metal girder structure. Employee 1 was hospitalized with a fractured right leg, which required surgery to repair.

Source

Authoritative
OSHA Severe Injury Reports
Machine