← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 20241111017 · 11/27/2024 · Dot Foods, Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Fans, blowers wall, floor, ceiling, ventilation
Secondary source
Drives, belts, chains

Employer

Name
Dot Foods, Inc.
Location
1 Dot Way, MOUNT STERLING, ILLINOIS, 62353
NAICS
424490
Jurisdiction
1

Narrative

An employee was performing preventative maintenance on an exhaust fan on the roof of the engine room. When the employee removed the lid to the exhaust fan, his hand slipped and contacted the belt inside the fan. The tip of his left ring finger was amputated.