← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation, 1 hospitalization · 20241211163 · 12/3/2024 · Proampac Orlando Inc.

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Metal, woodworking, and special material machinery unspecified
Secondary source
Secondary source not applicable

Employer

Name
Proampac Orlando Inc.
Location
1200 Central Florida Parkway, ORLANDO, FLORIDA, 32837
NAICS
423990
Jurisdiction
1

Narrative

On December 3, 2024, an employee was troubleshooting a metal cutting die when the punch die amputated her left middle fingertip.

Source

Authoritative
OSHA Severe Injury Reports
Machine