← OSHA severe injury reports

Fractures

1 hospitalization · 20241211435 · 12/10/2024 · Express Insulation Inc

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Trunk and other upper extremities
Nature of injury
Fractures

Cause

Event
Fall to lower level from collapsing structure or equipment unspecified
Source
Self-supporting scaffolds or staging
Secondary source
Constructed surface irregularity

Employer

Name
Express Insulation Inc
Location
339 Boston Post Rd. E., MARLBOROUGH, MASSACHUSETTS, 01752
NAICS
238310
Jurisdiction
1

Narrative

An employee was on a mobile scaffold when its wheel caught on a depression in the floor. The scaffold toppled over and the employee fell, suffering fractures to their ribs and shoulder as well as head injuries.

Source

Authoritative
OSHA Severe Injury Reports
Machine