← OSHA severe injury reports

Cuts, lacerations, punctures without injury to internal structures

1 hospitalization · 2025032206 · 3/7/2025 · Durex Products, Inc.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Wrist(s)
Nature of injury
Cuts, lacerations, punctures without injury to internal structures

Cause

Event
Injured by object held or wielded by person
Source
Box cutters, razor knives
Secondary source
Secondary source not applicable

Employer

Name
Durex Products, Inc.
Location
112 West First Avenue, LUCK, WISCONSIN, 54853
NAICS
332999
Jurisdiction
1

Narrative

On March 7, 2025, an employee was using a v-knife to manually remove flashing (waste material) from urethane parts when the v-knife slipped and it lacerated an artery in their left wrist.

Source

Authoritative
OSHA Severe Injury Reports
Machine