← OSHA severe injury reports

Fractures

1 hospitalization · 2025032410 · 3/13/2025 · Farr Foundation, Inc.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Ears and facial region unspecified
Nature of injury
Fractures

Cause

Event
Struck by running powered equipment irregular movement, kick back
Source
Pumps except oil well
Secondary source
Hoses except machine

Employer

Name
Farr Foundation, Inc.
Location
north I-35 service road across from texas travel information center, GAINESVILLE, TEXAS, 76240
NAICS
238110
Jurisdiction
1

Narrative

A crew was priming a cement pump. To help grout start moving through the pump, they ran a few gallons of water through it and started it in forward until the grout reached the end of the first 20-foot hose section. They then placed the pump in neutral, connected the next 20-foot hose with hose clamps, and began pumping again. As the grout traveled through the second hose, it clogged. The pump was put in neutral just as the hose kicked, and the motion traveled down the length of the hose. An employee was holding the end of the hose when it kicked up and struck him in the left side of the face, causing fractures.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown