← OSHA severe injury reports

Electrical burns and electrocution

1 hospitalization · 2025032978 · 3/31/2025 · T L Sund Constructors

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Body systems and other part(s) of body
Nature of injury
Electrical burns and electrocution

Cause

Event
Indirect exposure to electricity greater than 220 volts
Source
Power lines, transformers, convertors
Secondary source
Surfacing handtools n.e.c.

Employer

Name
T L Sund Constructors
Location
2700 Plum Creek Parkway, LEXINGTON, NEBRASKA, 68850
NAICS
238110
Jurisdiction
1

Narrative

An employee was finishing concrete with a float. He pulled the handle of the float up and it struck an overhead power line. The employee was shocked and lost consciousness. He also sustained burns to the face and left foot.