← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2025043623 · 4/18/2025 · HYDRO CONDUIT, LLC

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Caught or wedged between objects nonrunning
Source
Pipes, conduits concrete or clay
Secondary source
Pipes, conduits concrete or clay

Employer

Name
HYDRO CONDUIT, LLC
Location
13100 NW 118th Ave, MIAMI, FLORIDA, 33178
NAICS
238910
Jurisdiction
1

Narrative

An employee was patching a reinforced concrete pipe that was 36 inches in diameter and 8 feet long. The employee was on a patch line with his right hand placed on the outside of the pipe to use it for leverage. When the pipe transport dropped off the next pipe, it rolled and crushed his right hand between the two pipes, resulting in amputation of the ring fingertip.