← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2025043807 · 4/23/2025 · Parallel Products of Florida, LLC

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Caught or wedged between objects nonrunning
Source
Hydraulic and pressurized cylinders
Secondary source
Trash compactors, shredders

Employer

Name
Parallel Products of Florida, LLC
Location
15112 Packing House Road, DADE CITY, FLORIDA, 33523
NAICS
423930
Jurisdiction
1

Narrative

Employees were installing a hydraulic cylinder on a compactor. The injured employee completed rigging of the hydraulic cylinder and directed another employee to move the cylinder into place. At the same time, a third employee was preparing the cylinder pin for installation. The injured employee went to align the pin on the cylinder. The hydraulic cylinder shifted and pinched his left index finger between the cylinder and the compactor, resulting in amputation of the fingertip.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown