← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2025043886 · 4/25/2025 · Schleuniger, Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Metal, woodworking, and special material machinery unspecified
Secondary source
Machine guards

Employer

Name
Schleuniger, Inc.
Location
1100 Corporate Grove Drive, BUFFALO GROVE, ILLINOIS, 60089
NAICS
334419
Jurisdiction
1

Narrative

An employee was repairing a benchtop wire processing machine that is used to make wire harnesses for commercial applications. A guard had been removed in order to access the components. The employee was testing the "trigger" sensor of the machine and adjusting the blades when the machine actuated and a blade amputated part of his left index fingertip.

Source

Authoritative
OSHA Severe Injury Reports
Machine