← OSHA severe injury reports

Fractures and burns

1 hospitalization · 2025054203 · 5/5/2025 · J Lee Milligan Inc

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Part of body unspecified
Nature of injury
Fractures and burns

Cause

Event
Explosion unspecified
Source
Trucks with other mounted machinery, equipment n.e.c.
Secondary source
Rods, reinforcing bar (rebar) metal

Employer

Name
J Lee Milligan Inc
Location
9200 Triangle Drive, AMARILLO, TEXAS, 79108
NAICS
237310
Jurisdiction
1

Narrative

Employees were conducting maintenance on the clogged vent pipe of an asphalt distributor truck. The employees went to unclog the tank using a propane torch and a piece of steel rebar. They heated the tip of the rebar with the torch and put it inside the tank. An explosion and a fire occurred. Two employees were injured; one employee was hospitalized with fractured bones and first- and second-degree burns.