← OSHA severe injury reports

Fractures

1 hospitalization · 2025054669 · 5/19/2025 · Meiji America, Inc.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Forearm(s)
Nature of injury
Fractures

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Conveyors belt, slot, chain
Secondary source
Rollers, cylinders

Employer

Name
Meiji America, Inc.
Location
360 South Belmont Street, YORK, PENNSYLVANIA, 17403
NAICS
311821
Jurisdiction
1

Narrative

An employee was using an air hose to blow built-up dough off the rollers under the cutting apron on a conveyor belt line. The air stopped working and they went to manually remove the dough when their right hand was pulled into the pinch point between the apron and roller. The employee was hospitalized with a fracture to their right forearm that required surgery.

Source

Authoritative
OSHA Severe Injury Reports
Machine