← OSHA severe injury reports

Fractures and soft tissue injuries

1 hospitalization · 2025065278 · 6/3/2025 · PACEM Defense LLC

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Other finger(s) n.e.c.
Nature of injury
Fractures and soft tissue injuries

Cause

Event
Struck by running powered equipment unspecified
Source
Stamping machinery, presses except printing
Secondary source
Secondary source not applicable

Employer

Name
PACEM Defense LLC
Location
4700 Providence Rd, PERRY, FLORIDA, 32347
NAICS
325920
Jurisdiction
1

Narrative

An employee was making a fine adjustment after a tooling change on a pyrotechnic pellet press when the machine interface was actuated. The bottom piston on the press crushed his left hand, resulting in fractures to his index, middle, and ring fingers with tendon damage to the middle finger. The employee was hospitalized and required surgery.

Source

Authoritative
OSHA Severe Injury Reports
Machine