← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation, 1 hospitalization · 2025065773 · 6/17/2025 · Salem Tube, Inc.

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Other finger(s) n.e.c.
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Metal, woodworking, and special material machinery unspecified
Secondary source
"Lock out/ tag out" communication systems

Employer

Name
Salem Tube, Inc.
Location
485 Nickel Street, GREENVILLE, PENNSYLVANIA, 16125
NAICS
331210
Jurisdiction
1

Narrative

An employee was removing a tube that was stuck in a draw bench. The tube activated a sensor that dropped the inserter down, causing the tube to pull the employee's left little finger into the tube and the inserter wheels. The employee sustained a partial amputation and was hospitalized. The machine was not locked out at the time.

Source

Authoritative
OSHA Severe Injury Reports
Machine