← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2025065899 · 6/20/2025 · Smithfield Foods, Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Packaging, wrapping, bundling machinery
Secondary source
Machine guards

Employer

Name
Smithfield Foods, Inc.
Location
2323 S Sheridan Street, WICHITA, KANSAS, 67213
NAICS
311612
Jurisdiction
1

Narrative

An employee was operating a packaging machine and went to unjam some plastic. Her left hand contacted the cutting blades resulting in a partial amputation to the middle fingertip. A guard was in place at the time.

Source

Authoritative
OSHA Severe Injury Reports
Machine