← OSHA severe injury reports

Traumatic injuries or exposures unspecified

1 hospitalization · 2025077418 · 7/29/2025 · RTS Companies (US), Inc

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Hand(s), finger(s) unspecified
Nature of injury
Traumatic injuries or exposures unspecified

Cause

Event
Struck by running powered equipment irregular movement, kick back
Source
Routers, molders
Secondary source
Secondary source not applicable

Employer

Name
RTS Companies (US), Inc
Location
2900 Industrial Park Dr., AUSTINBURG, OHIO, 44010
NAICS
326199
Jurisdiction
1

Narrative

An employee was cutting a piece of plastic molding with a handheld router when the router kicked out and contacted the employee's right thumb. The employee was hospitalized with hand injuries that required repair.

Source

Authoritative
OSHA Severe Injury Reports
Machine