← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2025087952 · 8/12/2025 · Flextronics America, LLC

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Caught or wedged between objects nonrunning
Source
Vehicle and machine parts unspecified
Secondary source
Vehicle and machine parts unspecified

Employer

Name
Flextronics America, LLC
Location
12455 Research Blvd., AUSTIN, TEXAS, 78759
NAICS
334418
Jurisdiction
1

Narrative

An employee was replacing a linear motor shaft (a highly magnetic object) on a machine. The new shaft was placed on a work table next to the old shaft. Magnetism caused the two shafts to come together quickly and crush the employee's right middle fingertip. The employee suffered a degloving/amputation from the top of the fingernail.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown