← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2025088002 · 8/12/2025 · Connecto Electric, Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Other finger(s) n.e.c.
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Caught, entangled in running powered equipment normal operation
Source
Drills, braces, drivers
Secondary source
Gloves, handguards except disposable, electric insulating

Employer

Name
Connecto Electric, Inc.
Location
1029 Pittsburgh Ave, ERIE, PENNSYLVANIA, 16505
NAICS
238210
Jurisdiction
1

Narrative

Employees were drilling a hole through a brick-and-mortar fa ade so that conduit could be run into the building. A hammer drill began to wobble as it was used to bore the hole. An employee went to steady the drill and the drill bit caught and twisted their glove, causing an amputation to their right middle finger.

Source

Authoritative
OSHA Severe Injury Reports
Machine