← OSHA severe injury reports

Amputations, avulsions, enucleations unspecified

1 amputation · 2025088449 · 8/24/2025 · Harbor Freight Tools Texas L.P.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger or thumb tip(s), nail(s)
Nature of injury
Amputations, avulsions, enucleations unspecified

Cause

Event
Struck by running powered equipment during maintenance, cleaning, testing
Source
Conveyors belt, slot, chain
Secondary source
Machine guards

Employer

Name
Harbor Freight Tools Texas L.P.
Location
3401 S Brandon Rd, ELWOOD, ILLINOIS, 60421
NAICS
493110
Jurisdiction
1

Narrative

An employee was re-tensioning the pulleys on a conveyor belt in a shipping merge. He restarted the conveyor and his right index finger got caught in the belt, which pulled it into a pulley and amputated the top of the finger just past the fingertip. The pulleys were not guarded at the time of the incident.